Wall average heat transfer in CFB boilers / Breitholtz C,Leckner B,Baskakov AP // POWDER TECHNOLOGY. - 2001. - V. 120, l. 1-2, SI. - P. 41-48.

ISSN/EISSN:
0032-5910 / нет данных
Type:
Article; Proceedings Paper
Abstract:
The purpose of this work is to find a correlation for heat transfer to walls in circulating fluidized bed (CFB) boilers. Heat transfer and suspension density data from six boilers in the range from 12 to 300 MWth, form the basis of the correlation. The data were averaged over the entire height of the heat-receiving wall to facilitate application to boilers. Averaging also reduces uncertainties in the measured data. The correlation of heat transfer coefficient (HTC) and average suspension density represents the measured heat transfer coefficients within 15\%. An attempt to separate radiation and convection was made in order to account for variations in wall and bed temperatures. The improvement due to the separate treatment is not significant compared to the uncertainty in the experimental data, but the influence of temperature on the heat transfer coefficient is explicitly represented. (C) 2001 Elsevier Science B.V. All rights reserved.
Author keywords:
circulating beds; fluidized beds; boiler; heat transfer CIRCULATING-FLUIDIZED-BED; COMBUSTOR; FURNACE; SIZE
DOI:
10.1016/S0032-5910(01)00345-X
Web of Science ID:
ISI:000171623200006
Соавторы в МНС:
Другие поля
Поле Значение
Month OCT 8
Note 3rd European Conference on Fluidisation (EUROFLUIDISATION III), TOULOUSE, FRANCE, MAY 28-31, 2000
Publisher ELSEVIER SCIENCE SA
Address PO BOX 564, 1001 LAUSANNE, SWITZERLAND
Language English
Keywords-Plus CIRCULATING-FLUIDIZED-BED; COMBUSTOR; FURNACE; SIZE
Research-Areas Engineering
Web-of-Science-Categories Engineering, Chemical
ResearcherID-Numbers Leckner, Bo/I-8091-2015
Number-of-Cited-References 26
Usage-Count-Since-2013 3
Journal-ISO Powder Technol.
Doc-Delivery-Number 483FP